Cisco CX-FEIP-1TX= Installation and con?guration Guía de usuario Pagina 388

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 648
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 387
Testing the ODU and IF cable Chapter 5: Installation
5-66
phn-2513_004v000 (Oct 2012)
Expected cable loss
Table 215 quotes the expected cable loss for given cable lengths when the ODU is not
connected. All loss figures have a tolerance of plus or minus 10%, for example, 1.76 dB
means that the loss is expected to be between 1.58 and 1.94 dB.
Table 215 Expected cable loss when ODU is not connected
Cable
Length
(meters)
Cable Loss
(+/- 10%) at
350 MHz (dB)
Cable Loss (+/- 10%) with two
Lightning Protection Units fitted,
at 350 MHz (dB)
1 0.08 0.3
2 0.15 0.37
3 0.23 0.45
4 0.31 0.53
5 0.39 0.61
6 0.46 0.68
7 0.54 0.76
8 0.62 0.84
9 0.69 0.91
10 0.77 0.99
20 1.54 1.76
30 2.31 2.53
40 3.08 3.3
50 3.85 4.1
100 7.7 7.92
Vista de pagina 387
1 2 ... 383 384 385 386 387 388 389 390 391 392 393 ... 647 648

Comentarios a estos manuales

Sin comentarios