PTP 800 Series User Guide Managing performance
phn-2513_004v000 (Oct 2012)
7-59
Table 261 System Statistics and Counters attributes
Attribute Meaning
System Statistics
Transmit Power The maximum, mean, minimum and latest measurements of
Transmit Power.
Receive Power The maximum, mean, minimum and latest measurements of
Receive Power.
Vector Error The maximum, mean, minimum and latest measurements of
Vector Error.
Normalized Mean Square Vector Error is a measure of quality
for the received signal after all corrections made by the
demodulator. The value is generally in the range from -3 dB to -
35 dB. A more negative number indicates a higher quality
signal.
Link Loss The maximum, mean, minimum and latest measurements of Link
Loss.
Link Loss is a measurement of the loss in signal level as the
radio wave propagates between the antennas installed at each
end of the link. It is determined by measurement of the receive
level, the transmit power of the remote end and the antenna
gains and feeder losses at each end of the link.
The Link Loss is therefore only accurate if the correct antenna
gains and feeder losses have been configured at both ends of the
link.
Link Loss (dB) = Remote Transmit Power (dBm) - Remote
Feeder Loss (dB) + Remote Antenna Gain (dBi) + Local Antenna
Gain (dBi) - Local Feeder Loss (dB) - Local Receive Power
(dBm).
Transmit Data Rate The data rate in the transmit direction, expressed in Mbps and
presented as: max, mean, min, and latest in an histogram
format. The max, min and latest are true instantaneous
measurements; the mean is the mean of a set of one second
means.
Receive Data Rate The data rate in the receive direction, expressed in Mbps and
presented as: max, mean, min, and latest in an histogram
format. The max, min and latest are true instantaneous
measurements; the mean is the mean of a set of one second
means.