Task 5: Configuring security Chapter 6: Configuration and alignment
6-40
phn-2513_004v000 (Oct 2012)
Table 226 HTTP and Telnet attributes
Attribute Meaning
HTTPS Port
Number
The port number for HTTPS access. A value of zero means the
wireless unit uses the default port.
HTTPS access is controlled by license key.
HTTP Access
Enabled
‘No’ means that the unit will not respond to any requests on the
HTTP port.
‘Yes’ means that the unit will respond to requests on the HTTP
port.
Remote management via HTTPS is not affected by this setting.
HTTP Port
Number
The port number for HTTP access. A value of zero means the
wireless unit uses the default port.
Telnet Access
Enabled
‘No’ means that the unit will not respond to any requests on the
Telnet port.
‘Yes’ means that the unit will respond to requests on the Telnet
port.
Telnet Port
Number
The port number for Telnet access. A value of zero means the
wireless unit uses the default port.
SNMP Control of
HTTP And Telnet
‘Disabled’ means that neither HTTP nor Telnet can be controlled
remotely via SNMP.
‘Enabled’ means that both HTTP and Telnet can be controlled
remotely via SNMP.
Debug Access
Enabled
‘Yes’ means that Cambium Technical Support is allowed to
access the system to investigate faults.
If HTTP, Telnet and SNMP are all disabled (as required for FIPS 140-2 mode), the secure
web server becomes the only management tool for the CMU web interface. To reenter the
web interface after Step 7 of the Security Wizard, use the URL https://aa.bb.cc.dd
(where aa.bb.cc.dd is the IP address of the unit).