Juniper Networks/Cisco Systems Switch Interoperability Cookbook
! ! !
10
Topology!
Figure 2 shows the GRE validation test bed. This example uses a GRE tunnel between a
Juniper Virtual Chassis (here, comprising two Juniper EX9208 switches) and a Cisco
Nexus 7010 switch. The GRE tunnel endpoints are in the 192.18.44.0/24 subnet, and the
tunnel uses a 10-gigabit Ethernet link between switches.
Even though a different subnet (192.18.38.0/24) is configured on the physical interfaces
of both switches, traffic will traverse the GRE tunnel. In this example, the Juniper and
Cisco devices use OSPF to learn about network reachability.
!"#$%&'5)'678'9.3":.0"2;'02-232#4'
!
Juniper!commands!
1. Define IP addresses on the inter-switch link and the link to the Spirent TestCenter
traffic generator/analyzer. Note that these addresses are associated with the physical
interfaces, not the GRE tunnel:
admin@ex9208> configure
admin@ex9208# set interfaces xe-5/0/5 description "physical interface to
Nexus 7010 e3/9"
admin@ex9208# set interfaces xe-5/0/5 unit 0 family inet address
192.18.38.1/24
admin@ex9208# set interfaces ge-2/0/0 description "physical interface to
STC"