Juniper Networks/Cisco Systems Switch Interoperability Cookbook
! ! !
49
Juniper!configuration!
1. Assign an IP address of 192.18.0.10/24 to interface xe-5/3/1:
admin@EX9208> configure
admin@EX9208# set interfaces ge-0/0/22 unit 0 family inet address
192.18.0.10/24
2. Define an RPM probe and test for the Cisco switch at 192.18.0.1:
admin@EX9208# set services rpm probe myprobe test t1 probe-type icmp-ping-
timestamp
admin@EX9208# set services rpm probe myprobe test t1 target address
192.18.0.1
admin@EX9208# set services rpm probe myprobe test t1 probe-count 10
admin@EX9208# set services rpm probe myprobe test t1 probe-interval 1
admin@EX9208# set services rpm probe myprobe test t1 test-interval 15
admin@EX9208# set services rpm probe myprobe test t1 data-size 128
admin@EX9208# commit
Note that although only ICMP is used here, a single probe can encompass multiple tests
using multiple types of health checks.
Cisco!configuration!
1. Assign an IP address of 192.18.0.1/24 to the monitored interface (in this case
TenGigabitEthernet1/1/3):
Cat3850# configure terminal
Cat3850(config)# interface GigabitEthernet1/1/3
Cat3850(config-if)# no switchport
Cat3850(config-if)# ip address 192.18.0.1 255.255.255.0
Cat3850(config-if)# end
Cisco Nexus 7000 switches running the NX-OS operating system also require an explicit
no shutdown” command to enable an interface.
No RPM-specific configuration is needed on the Cisco switch, or on any other device
monitored using RPM.
!