© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Inf ormation. Page 33 of 62
Last switchover reason = none
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso
Switch 1 Slot 1 Processor Information :
-----------------------------------------------
Current Software state = ACTIVE
Uptime in current state = 1 day, 19 hours, 30 minutes
Image Version = Cisco IOS Software, s72033_rp Software (s72033_rp -
ADVENTERPRISEK9_WAN_DBG-VM), Version 12.2(SIERRA_INTEG_070530) INTERIM SOFTWARE
Synced to V122_32_8_11, 12.2(32.8.11)SR on rainier, Weekly 12.2(32.8.11)SX85
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Thu 31-May-07 02:23 by kchristi
BOOT = sup-bootdisk:s72033-adventerprisek9_wan_d/jointfilesconvert/332885/bg-vz.SIERRA_INTEG_070530,1;
CONFIG_FILE =
BOOTLDR =
Configuration register = 0x2102
Fabric State = ACTIVE
Control Plane State = ACTIVE
Switch 2 Slot 1 Processor Information :
-----------------------------------------------
Current Software state = STANDBY HOT (switchover target)
Uptime in current state = 1 day, 19 hours, 30 minutes
Image Version = Cisco IOS Software, s72033_rp Software (s72033_rp -
ADVENTERPRISEK9_WAN_DBG-VM), Version 12.2(SIERRA_INTEG_070530) INTERIM SOFTWARE
Synced to V122_32_8_11, 12.2(32.8.11)SR on rainier, Weekly 12.2(32.8.11)SX85
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2007 by Cisco Systems, Inc.
Compiled Thu 31-May-07 02:23 by kchristi
BOOT = sup-bootdisk:s72033-adventerprisek9_wan_d/jointfilesconvert/332885/bg-vz.SIERRA_INTEG_070530,1;
CONFIG_FILE =
BOOTLDR =
Configuration register = 0x2102
Fabric State = ACTIVE
Control Plane State = STANDBY
As this output indicates, if a failure occurs in the active supervisor engine or the active virtual switch, a SSO
switchover is invoked, and the hot-standby supervisor engine in switch 2 assumes the role as the active supervisor
engine for the Cisco Virtual Switching System. This switchover should take approximately 50 ms.