White Paper
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Inf ormation. Page 42 of 62
Figure 27. Quad-Sup Uplink Forw arding
Hot-Standby Supervisor Engine Failure
You can detect the failure of the hot-standby supervisor engine in the following ways:
Redundancy framework heartbeats sent across the VSL by the active supervisor
Full VSL link-down situation
Cisco Generic Online Diagnostics GOLD failure event
Upon detecting the failure of the hot-standby supervisor engine, the active supervisor engine simulates an OIR
removed event for all modules in the standby virtual switch. This simulation is performed because the modules on the
remote chassis have no connectivity because VSL communication to the modules is proxied by the local supervisor-
engine CPU (Figure 28).
Figure 28.
The effect on the data path is that all line cards on the standby virtual switch are brought down. Assuming that
adjacent devices are dual-homed to both the active virtual switch and standby virtual switch, only those flows being
forwarded through the standby virtual switch are affected, and the time to recovery depends on the mechanism used
to detect the link failure (Cisco EtherChannel technology, Layer 3 load balancing, or Spanning Tree Protocol). Upon
detecting that the interface connected to the standby virtual switch has failed, traffic resorts to using the link to the
active supervisor engine. Those data flows passing through the active virtual switch are not affected. The control
plane is not affected because the control-plane functions remain on the active supervisor engine on the active virtual
switch. The control plane experiences a removal of all of the standby virtual switch interfaces.