Cisco WS-C3550-24-FX-SMI - Catalyst 3550 100BASE-FX Switch Guía de instalación Pagina 92

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 150
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 91
Chapter3 Troubleshooting
Diagnosing Problems
3-4
Catalyst 3550 Multilayer Switch Hardware Installation Guide
78-11358-03
No connectivity Incorrect or bad cable
The following are results of no link
at both ends:
A crossover cable was used
when a straight-through was
required, or vice-versa.
The cable is wired incorrectly.
A crossover or straight-through
cable is wired incorrectly.
STP checking for possible
loops.
For the correct pinouts and
the proper application of
crossover vs.
straight-through cables, see
the Two Twisted-Pair
Cable Pinouts section on
page B-7.
Replace with a tested good
cable.
For 1000BASE-T
connections, be sure to use
a twisted four-pair,
Category 5 cable.
Wait 30 seconds for the port
LED to turn green.
Switch not recognizing a GBIC
module.
Refer to the your GBIC
documentation for more
information.
Unreadable characters on the
management console
Incorrect baud rate. Reset the emulation software to
9600 baud.
Table 3-2 Common Problems and Their Solutions (continued)
Symptom Possible Cause Resolution
Vista de pagina 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 149 150

Comentarios a estos manuales

Sin comentarios