McAfee® IntruShield® IPS 4.1 Attaching Cables to the M-6050
M-6050 Sensor Product Guide Cabling for in-line
Note: You cannot configure, for example, IA and 2A to work together as a pair.
Figure 9: Port pair
Default monitoring port speed settings
Be sure that the switch/router ports connected to the sensor Monitoring ports match
the sensor configuration.
Default monitoring port speed settings
Monitoring Ports Operating Mode Speed/Duplex Setting
XFP ports
SFP ports
SPAN Auto-negotiation is ON
Tap Auto-negotiation is ON
In-line Auto-negotiation is ON
Cable types for routers, switches, hubs, and PCs
The cabling instructions in this chapter
Use a crossover Ethernet RJ-45 cable to connect a router port to the
10/100/1000 copper SFP Monitoring ports.
Use a straight-through Ethernet RJ-45 cable to connect a switch/hub port to
10/100/1000 copper SFP Monitoring ports.
Use a crossover Ethernet RJ-45 cable to connect a router port to PC to the
sensor Management port.
Note: You should also use a crossover Ethernet RJ-45 cable to connect a PC to the
sensor monitoring port.
Cabling for in-line
The Gigabit Ethernet ports fail closed, meaning they stop the flow of traffic if the
sensor fails. To allow traffic to flow uninterrupted, you must use special hardware and
cable the sensor for fail-open functionality. For instructions, see the section later in
this chapter.
To connect the M-6050’s Gigabit Ethernet ports so they fail closed: