Environmental Monitoring and Reporting Overview for the Cisco 7500 Series
If the environmental status is not normal, the system reports the worst-case status level in the last line of
the display.
In the Cisco 7513 and Cisco 7513-MX, the show environment last command retrieves and displays the
NVRAM log showing the reason for the last shutdown (if the shutdown was related to voltage or
temperature) and the environmental status at that time. Air temperature is measured and displayed; the
DC voltages supplied by the power supply are also displayed.
Following is sample output of the show env last command:
Router# show env last
Environmental Statistics
Environmental status as of Wed 5-10-1995 16:42:48
Data is 10 second(s) old, refresh in 50 second(s)
All Environmental Measurements are within specifications
LAST Environmental Statistics
Environmental status as of Wed 5-10-1995 12:22:43
Power Supply: 1200W, OFF
No Intermittent Powerfails
+12 volts measured at 12.05(V)
+5 volts measured at 4.82(V)
-12 volts measured at -12.00(V)
+24 volts measured at 23.90(V)
Air-Flow temperature measured at 32(C)
Inlet temperature measured at 26(C)
RSP(6) Inlet previously measured at 27C/80F
RSP(6) Hotpoint previously measured at 38C/100F
RSP(6) Exhaust previously measured at 31C/87F
+12 Voltage previously measured at 12.17
+5 Voltage previously measured at 5.19
-12 Voltage previously measured at -12.17
+24 Voltage previously measured at 23.40
In the Cisco 7513 and Cisco 7513-MX, the show environment table command displays the temperature
and voltage thresholds for each of the three RSP temperature sensors for each monitored status level:
low critical, low warning, high warning, and high critical, which are the same as those listed in Table 2-6
and Table 2-7. The slots in which the RSP can be installed are indicated in parentheses (slot 6 and slot
7). Also listed are the shutdown thresholds for the processor boards and power supplies.
Following is sample output of the sh env table command:
Router# show env table
Environmental Statistics
Environmental status as of Wed 5-10-1995 18:50:21
Data is 46 second(s) old, refresh in 14 second(s)
WARNING: Fan has reached CRITICAL level
Voltage Parameters:
SENSE CRITICAL NORMAL CRITICAL
-------|--------------------|------------------------|------------------
+12(V) 10.20 12.05(V) 13.80
+5(V) 4.74 4.96(V) 5.76
-12(V) -10.20 -12.05(V) -13.80