REVIEW DRAFT—CISCO CONFIDENTIAL
3-32
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 3 Installing a Cisco 7500 Series Router
Making Cable Connections to the RSP
Making Cable Connections to the RSP
This section describes how to make cable connections to the console and auxiliary ports on the RSPs in
the Cisco 7500 series routers. (Specific differences between RSPs are clearly noted.)
Note Pinouts for the console and auxiliary ports and cables are listed in the RSP Asynchronous Serial
PortsConsole and Auxiliary section on page 1-44.
Connecting a Console Terminal to the RSP
The system console port on the RSP is a DB-25 receptacle DCE port for connecting a data terminal,
which will allow you to configure and communicate with your system. Use the console cable provided
to connect the terminal to the console port on the RSP. The console port is located on the RSP next to
the auxiliary port, as shown in Figure 3-22, and is labeled Console. (The RSP in the Cisco 7505 is
oriented horizontally.)
Before connecting the console port, check your terminals documentation to determine the baud rate of
the terminal you will be using. The baud rate of the terminal must match the default baud rate (9600
baud). Set up the terminal as follows: 9600 baud, 8 data bits, no parity, and 2 stop bits (9600,8N2).
Figure 3-22 Console and Auxiliary Port Connections (All RSPs)
Note Both the console and auxiliary ports are asynchronous serial ports; any devices connected to these ports
must be capable of asynchronous transmission. (Asynchronous devices are the most common type of
serial devices; for example, most modems are asynchronous devices.)
Connecting to the Auxiliary Port
The auxiliary port on the RSP is a DB-25 plug DTE port for connecting a modem or other DCE device
(such as a CSU/DSU or another router) to the router. The port is located next to the console port on the
RSP and is labeled AUX. An example of a modem connection is shown in Figure 3-22.
122370
Modem
Console terminal
Auxiliary
port
Console
port
DB-25 female
DB-25 male
RSP