40 DGVox 8 Management Console Configuration Guide
Chapter 1 - Management Console
Confidential and Proprietary Information of Vox Spectrum. Ltd.
Select the appropriate control option from the drop-down
list. The options are:
HOOK – The recording is triggered based on the
channel events of digital recorder.
SILENCE - The recording is triggered if there is a
voice, and stopped if there is silence.
COMMAND - It is a reserve mode, in which the
recording triggers from the third party components
or software.
Type the silence threshold in dBm.
The range of the silence threshold is 0 to -60.0 dBm.
By default, the silence threshold is -51.0 dBm.
Type the activity threshold in dBm.
The range of the activity threshold is 0 to -60.0 dBm.
By default, the activity threshold is -48.0 dBm.
Type the minimum activity time in milliseconds. This is
the amount of noise-time, in milliseconds, required to
enter the activity detected state.
Type the maximum activity time in milliseconds. This is
the maximum time that activity has to be present, before
the Max activity event is issued.
Type the minimum silence time in milliseconds. This field
displays the amount of time, in milliseconds, required to
enter the silence detected state.
Type the maximum silence time in milliseconds. This is
the maximum time of silence, before the Maximum
silence event is issued.
Type the audio gain required. A fixed gain stage is
provided to adjust the overall amplitude of the received
voice data.
Signals with energy lower then the target will be
amplified to reach the target level. The amount of
amplification is limited by a parameter MA.
Comentarios a estos manuales