2-7
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Installing Voice and WAN Interface Modules
Note VICs, WICs, and VWICs do not support online insertion and removal (hot swapping).
Caution Before inserting a VIC, WIC, or VWIC into the AGM, you must turn off the electrical power by
either powering off the switch or unplugging the AGM from the chassis and disconnecting the
network cables.
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning
This equipment is to be installed and maintained by service personnel only as defined by AS/NZS
3260 Clause 1.2.14.3 Service Personnel.
Warning
Incorrect connection of this or connected equipment to a general purpose outlet could result in a
hazardous situation.
Warning
The telecommunications lines must be disconnected 1) before unplugging the main power
connector and/or 2) while the housing is open.
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is
OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching
cables, detach the end away from the unit first.
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to
telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports
contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when
connecting cables.
Warning
Network hazardous voltages are present in the BRI, fractional T1/T1, and Switched 56 cables. If
you detach the cable, detach the end away from the router first to avoid possible electric shock.
Network hazardous voltages are also present in the area of the BRI (RJ-45), fractional T1/T1
(RJ-48C), and Switched 56 (RJ-11 or RJ-48S) ports, regardless of whether power is off or on.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
To install a VIC/WIC, perform these steps:
Step 1 If the switch is powered on, remove the AGM from the chassis or power off the chassis.
Step 2 Remove all network interface cables, including telephone cables, from the front panel.