4-3
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 4 Configuring the Data Interfaces
Configuring the Fast Ethernet Interface
To verify that you configured the correct host name and password, perform these steps:
Step 1 Enter the show config command:
gwy1# show config
Using 1888 out of 126968 bytes
!
version XX.X
.
.
.
!
hostname gwy1
!
enable secret 5 $1$60L4$X2JYOwoDc0.kqa1loO/w8/
.
.
.
Check the host name and encrypted password displayed near the top of the command output.
Step 2 Exit global configuration mode and attempt to reenter it using the new enable password:
gwy1# exit
.
.
.
gwy1 con0 is now available
Press RETURN to get started.
gwy1> enable
Password: guessme
gwy1#
Tip If you are having trouble, verify that the Caps Lock function is off; passwords are case
sensitive.
Configuring the Fast Ethernet Interface
This section describes how to configure the Fast Ethernet interface on the AGM.
Timesaver Before you begin, disconnect all WAN cables from the AGM to keep it from trying to run the
AutoInstall process. The AGM tries to run AutoInstall whenever you bring the module online if there
is a WAN connection on both ends and the AGM does not have a valid configuration file stored in
NVRAM (for instance, when you add a new interface). The AGM can take several minutes to
determine that AutoInstall is not connected to a remote TCP/IP host.