2-21
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting the Voice and WAN Interface Modules
Step 1 Power off the AGM.
Step 2 Connect one end of the RJ-11 cable to one of the RJ48S ports of the module, as shown in Figure 2-14.
Step 3 Connect the other end of the cable to the RJ48S wall jack, as shown in Figure 2-14.
Figure 2-14 Connecting a 2-Port E/M Module (VIC-2E/M)
Step 4 Power on the AGM.
Step 5 verify the IN USE LED is green, indicating that line is in use.
Table 2-8 describes the E/M voice interface module LED.
Connecting the 2-Port ISDN BRI Modules
This section describes how to connect and verify the status of the 2-port ISDN BRI modules
(VIC-2BRI-S/T-TE).
Use the straight through RJ-48C-to-RJ-48C cable that shipped with your AGM.
To connect the 2-port ISDN BRI module, perform these steps:
Step 1 Power off the AGM.
Step 2 Connect one end of the cable to one of the RJ-48C ports of the module, as shown in Figure 2-15.
Step 3 Connect the other end of the cable to one of the RJ-48C S/T ports on an NT1 device, as shown in
Figure 2-15.
Straight-through
RJ-11-to-RJ-11 cable
RJ-48S ports
RJ-48S wall jack
58546
SEE MANUAL BEFORE INSTALLATION
VIC
E&M
IN USE
IN USE
1
0
Table 2-8 E/M Voice Interface Module LED
LED Description
IN USE Green indicates that the line is active.