2-12
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting the Voice and WAN Interface Modules
• Synchronous modem
• DSU/CSU
• Other DCE, if connecting to a digital WAN line
To connect the 2-port A/S serial module, perform these steps:
Step 1 Power off the AGM.
Step 2 Connect one end of the appropriate serial cable to a DB-60 port on the module, as shown in Figure 2-6.
Step 3 Connect the other end of the cable to the appropriate type of equipment, as shown in Figure 2-6.
Step 4 Power on the AGM.
Step 5 Verify that the CONN LED goes on, indicating that the serial port on the module detects the WAN serial
connection.
Figure 2-6 Connecting a 2-Port A/S Serial Module (WIC-2A/S)
Table 2-3 describes the 2-port A/S serial interface module LED.
Connecting the 1-Port and 2-Port Serial Modules
This section describes how to connect and verify the status of the 1- and 2-port serial modules (WIC-1T
and WIC-2T).
Note The AGM does not support asynchronous mode operation at this time.
SERIAL
Serial transition
cable
DSU/CSU or
other DCE
EIA/TIA-232, EIA/TIA-449, V.35,
X.21, or EIA-530 connector
H7370
Synchronous serial
port (DB-60)
CONN LED
CONN
Table 2-3 Asynchronous/Synchronous WAN Interface Module LED
LED Description
CONN Green indicates that the serial port detects a WAN serial connection.