Vista de pagina 50
2-25
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting a Terminal to the Console and Ethernet Management Ports
Step 5 Verify that the CD LED is green, indicating that the module’s internal DSU/CSU is communicating with
the DSU/CSU at the T1 or E1 service provider CO.
Table 2-11 describes the 2-port multiflex interface module LEDs.
If you have additional modules to install, proceed to the appropriate section in this document.
Connecting a Terminal to the Console and Ethernet Management
Ports
The console and 10/100 Mbps Ethernet management ports are located on the front panel of the AGM.
(See Figure 2-1) The console and Ethernet management ports use an RJ-45 media-dependent interface
crossed-over (MDIX) connector (see Figure 2-18). Table 2-12 lists the console port pinouts and
Table 2-13 lists the 10/100 Mbps Ethernet management port pinouts.
Note The MDIX ports are crossed over internally. For an MDI-to-MDI or MDIX-to-MDIX connection,
use a crossover cable. For an MDI-to-MDIX connection, use a straight-through cable, which allows
the Tx pins to connect with the Rx pins.
Figure 2-18 10/100Base-TX RJ-45 Connector Type
Table 2-11 2-Port Multiflex Trunk Interface Module LEDs
LED Description
AL Yellow indicates that there is a local or remote alarm state.
This LED is off during normal operation.
LP Yellow indicates that a loopback or line state has been
detected or has been manually set by the user. This LED is
off during normal operation.
CD Green indicates that a carrier has been detected and that the
internal DSU/CSU in the module is communicating with
another DSU/CSU. This LED is on during normal
operation.