2-19
Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting the Voice and WAN Interface Modules
Figure 2-12 Pinout Convention for the Telco RJ-21
See Table C-3 in Appendix C, “Connector and Cable Specifications” for a mapping of the RJ-21 pinouts
for the 8-port FXS module connector.
Connecting the 2-Port FXO Voice Interface Modules
This section describes how to connect and verify the status of the 2-port FXO voice interface modules
(VIC-2FXO, VIC-2FXO-M1, VIC-2FXO-EU, VIC-2FXO-M2, and VIC-2FXO-M3).
Setting the Jumpers on the 2-Port FXO Module
The 2-port FXO voice interface module includes two jumper headers (W3 and W4) that you can use to
set loop-start or ground-start mode. One jumper configures each FXO port. The default setting is loop
start. In the default setting, jumpers are placed over positions 2 and 3 of headers W3 and W4.
Updated modern CO equipment, such as the DMS-100 and 5ESS switches, provides the CPC and ROS
features on loop-start lines. CPC provides faster disconnection, and ROS minimizes glare (collision of
inbound and outbound calls on the same interface). If your CO does not provide these features on
loop-start lines, you may want to configure the FXO module for ground-start operation instead by
moving the jumpers to positions 1 and 2.
For proper operation, you must configure both jumpers identically. In most cases, the jumper setting
should have little or no effect on operation.
Note This jumper setting does not apply to VIC-2FXO-EU.
Connecting the 2-Port FXO Module
Use a standard RJ-11 modular telephone cable to connect the 2-port FXO module to the PSTN or PBX
through a telephone jack. To connect the 2-port FXO module, perform these steps:
Step 1 Power off the AGM.
Step 2 Connect one end of the cable to one of the RJ-11 ports of the module, as shown in Figure 2-13.
Step 3 Connect the other end of the cable to the RJ-11 wall jack, as shown in Figure 2-13.
50436
Ring
Tip
ConfigurableNot used
Grounds
Port 0Port 7Port 24Pin 25 Pin 1