Cisco Catalyst 4000 Access Gateway Module Installation and Configuration Note
OL-3008-01
Chapter 2 Installing the Access Gateway Module
Connecting the Voice and WAN Interface Modules
Figure 2-7 Connecting a 1- Port Serial Module (WIC-1T)
Step 4
Power on the AGM.
Step 5 Verify that the CONN LED goes on, indicating that the serial port on the module detects the WAN serial
connection.
Table 2-4 describes the serial WAN interface module LED.
Voice Interface Modules
This section describes how to connect the following voice interface modules:
• Connecting the 2-Port FXS Voice Interface Modules, page 2-14
• Connecting the 8-Port RJ21 FXS Voice Interface Modules, page 2-16
• Connecting the 2-Port FXO Voice Interface Modules, page 2-19
• Connecting the 2-Port E/M Voice Interface Modules, page 2-20
• Connecting the 2-Port ISDN BRI Modules, page 2-21
Connecting the 2-Port FXS Voice Interface Modules
This section describes how to connect and verify the status of the 2-port FXS voice interface module
(VIC-2FXS or VIC-2FXS-EU).
SERIAL
Serial transition
cable
DSU/CSU or
other DCE
EIA/TIA-232, EIA/TIA-449, V.35,
X.21, or EIA-530 connector
58519
Synchronous serial
port (DB-60)
CONN LED
CONN
Table 2-4 Serial WAN Interface Module LED
LED Description
CONN Green indicates that the serial port detects the WAN serial connection.