Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(32)S11
CSCsm75339
Symptoms: Tracebacks on mic-reload of SIP601.
Conditions: Mic-reload of SIP601 with CT3 SPA.
Workaround: Reloading the secondary RP should restore the out-of-sync ifindex tables.
CSCsm82600
Symptoms: PRP-1 fails to boot after an OIR/power cycle. LEDs might show RPT SENT or RP RDY.
Conditions: This symptom is observed upon a power cycle after upgrading the mbus-agent-rom of
the PRP.
Workaround: Use the upgrade mbus-agent-rom slot force command with an older version of
Cisco IOS software in the active RP to downgrade the mbus agent ROM of the problem RP.
CSCso21681
Symptoms: An output policy on an MFR interface disappears when the SIP 601 card is reset.
Conditions: Configure the service policy and apply it to the output of the MFR interface. Reset the
SIP 601 card, and the service policy will disappear from configuration.
Workaround: There is no workaround.
CSCso22730
Symptoms: Prefixes learned via IGP (ISIS) get assigned “imp-null” as the local label for them.
Conditions: The router has ECMP paths to uplink routers via POS interfaces. It runs ISIS as an IGP.
There could be TE tunnel configured on the POS interface. And frequent interface flaps.
Workaround: There is no workaround. Clear the route or flap the interface to bring back the correct
local label.
CSCso25848
Symptoms: With an ingress E2 GigE line card and an egress E5 line card, packets are dropped in the
egress line card with TX bad BMA buffer counts increasing.
Conditions: This symptom is observed when the ingress is E2 and the egress is E5.
Workaround: There is no workaround.
Further Problem Description: This issue is not seen with an E3/E5 combination or an E2/E6
combination.
CSCso31508
Symptoms: CEF and hardware CEF for global default route are inconsistent. This may cause the
default traffic to be sent through the wrong interface.
Conditions: This issue occurs under the following conditions:
1. Global default should point toward the core.
2. VRF default should be learned from the remote PE.
Workaround: Enter the following command:
clear ip route 0.0.0.0 0.0.0.0
CSCso32397
Symptoms: An unexpected reboot occurs because of a software-forced crash.
Conditions: This symptom is observed when changes are made in the policy map.
Workaround: There is no workaround.