676
Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(32)S
–
2-port Gigabit Ethernet SPA
–
4-port FE SPA
–
CT3 SPA
–
T1/E1 SPA
–
T3/E3 SPA
Workaround: There is no workaround.
• CSCeh64632
Symptoms: After a Route Processor or line card has reloaded, the queue limit that is set for the class
default is not properly programmed.
Conditions: This symptom is observed on a Cisco 12000 series 1-port channelized OC-12/STM-4
(DS1/E1) ISE line card that has an egress policy applied to a serial interface.
Workaround: There is no workaround.
• CSCeh65748
Symptoms: A Engine 3 ISE line card may not properly handle incoming bad IP packets but may
generate a traceback and a transient error message:
%GSR-3-INTPROC: Process Traceback= 400E10B4 400FBA2C
-Traceback= 4047917C 405E5274 400F4B58
%EE48-3-BM_ERRS: FrFab BM SOP error 40000
%EE48-3-BM_ERR_DECODE: FrFab SOP macsopi_bhdr_pkt_len_zero_err
%GSR-3-INTPROC: Process Traceback= 400E1090 400FBA2C
-Traceback= 4047917C 405E5274 400F4B58
%LC-4-ERRRECOVER: Corrected a transient error on line card.
The line card may also crash.
Conditions: These symptoms are observed on a Cisco 12000 series that runs Cisco IOS
Release 12.0(26)S1 or Release 12.0(26)S5a.
Workaround: There is no workaround.
• CSCeh66946
Symptoms: An interface stops traversing traffic through an Engine 6 2xOC192 POS line card.
Conditions: This symptom occurs when AToM is configured on an Engine 6 2xOC192 line card
(facing the edge).
Workaround: There is no workaround.
• CSCeh70093
Symptoms: The no form of a configuration command such as the no shutdown controller
configuration command may not be properly synchronized to the standby RP.
Conditions: This symptom is observed on a Cisco 12000 series that functions in SSO redundancy
mode and that is configured with a 6-port channelized T3 line card. When you enter the no
shutdown controller configuration command on the T3 controller of the 6-port channelized T3 line
card, the no shutdown configuration does not synchronize to the standby RP, and after an SSO
switchover has occurred, the T3 controller remains in the adminDown state on the newly active RP.
Workaround: Manually enter no shutdown controller configuration command on the T3 controller
after the RP switchover has occurred.