Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(32)S
Workaround: There is no workaround.
• CSCei36381
Symptoms: When QOS parameters are changed, traffic does not pass via an L2TPv3 link.
Conditions: This symptom is observed on a Cisco 12000 series that runs Cisco IOS
Release 12.0(31)S when QOS or HQoS parameters are changed and affect the traffic flow.
Workaround: Reload the affected line card or reload the router.
• CSCei37227
Symptoms: You cannot link a CoS slot table definition to a line card by entering the rx-cos-slot
global configuration command. When you attempt to do so, the following error message is
generated:
% Unknown Cos Queue Group - ToFab-Policy
Conditions: This symptom is observed on a Cisco 12000 series that runs the gsr-p-mz image of a
Cisco IOS interim release later than Release 12.0(31)S.
Workaround: There is no workaround.
• CSCei37523
Symptoms: When you reload all the line cards on a Cisco 12000 series or when you initiate an RP
switchover, a %PRP-3-CHP_DESCQ_FULL error message may be generated and some of the line
cards may fail.
Conditions: This symptom is observed on a Cisco 12000 series that runs a Cisco IOS interim release
later than Release 12.0(31)S when one of the clock and scheduler cards (CSCs) is shut down.
Workaround: Reload the affected line cards.
• CSCei38116
Symptoms: ISE line cards crash when a Cisco 12000 series receives 640,000 multicast streams.
Conditions: This symptom is observed when the memory of the ISE line cards becomes exhausted
when the thousands of multicast streams are received.
Workaround: There is no workaround.
• CSCei39383
Symptoms: Interface configuration parameters are not applied to the running configuration after an
RPR+ switchover.
Conditions: This symptom is observed intermittently on a Cisco 12000 series that is configured with
a 1-port CHOC-48 ISE line card but may also occur with other line cards.
Workaround: Apply the configuration manually to the affected interface.
• CSCei40168
Symptoms: An AToM VC that is configured on a Fast Ethernet or Gigabit Ethernet interface may
not be functional and packets that are received on the interface are dropped.
Conditions: This symptom is observed on a Cisco 10720.
Workaround: Reconfigure the xconnect command on the affected interface.
Further Problem Description: When the symptom occurs, the output of the show hardware pxf cpu
statistics interface interface-name detail command shows that the packets that are received on the
interface are dropped because of an “mpls undefined port” condition.