Cross-Platform Release Notes for Cisco IOS Release 12.0S
OL-1617-14 Rev. Q0
Caveats
Resolved Caveats—Cisco IOS Release 12.0(32)S9
Conditions: This problem is seen on a Cisco 12416 Internet Series router containing dual channelize
OC-48 line cards configured for automatic protection switching. The router is running Cisco IOS
Release 12.0(32)S6q.
Workaround: There is no workaround
CSCsk02675
Symptoms: RP crash occurs.
Conditions: Occurs when cef linecard is cleared concurrently with the unprovisioning of the
multilink bundle.
Workaround: Do not clear cef linecard and unprovision the bundle at the same time.
CSCsk05059
Symptoms: A spurious access error occurs in tfib_post_table_change_sanity_check () function.
Conditions: This symptom occurs if route is deleted. ROUTE_DOWN event is triggered in
tfib_post_table_change() function which in turn calls tfib_post_table_sanity_check(). In that
function, spurious access is reported, as the only path of route is down.
Workaround: There is no workaround.
CSCsk06322
Symptoms: "%REDUNDANCY-3-CONFIG_SYNC: Active and Standby lbl configuration out of
sync" message may be seen on hw-module shut of spas
Conditions: This is a timing issue and does not occur with debugs enabled.
Workaround: This does not impact service, and there is no workaround.
CSCsk08317
Symptoms: Hardware CHEF entry on line card is incorrect. Incorrect slot is observed by show hip
hardware-clef command.
Conditions: The problem occurs on Engine4+ Line Card of Cisco12000 router. The prefix has two
next hop with load balancing.
Workaround: Use the clear hip route <prefix> command to correct the problem.
CSCsk08440
Symptoms: E4+ card crashes continuously with following error:
SLOT X:Jul 29 09:40:52.844 UTC: %TX192-3-CPUIF_ERR: Underrun Error:
Read Pointer Crosses
Write Pointer.
-Traceback= 400310C4 411E4614 408E1934 4092B4C8 40A2FE1C 40A304F4
40110920
X=slot number
Conditions: Packets which have their IP header length corrupted hit the Tx E4+ card, and it causes
this fatal error, causing the line card to crash.
Workaround: There is no workaround.
CSCsk14113
Symptoms: This defect has two symptoms:
1. When changing the access lists used in LDP outbound filtering configuration tag-switching
advertise-tag for or mpls ldp advertise-label for, it may result in the LSR not advertising label
bindings for some prefixes.