475
Caveats for Cisco IOS Release 12.2(33)SRD through 12.2(33)SRD8
OL-10394-05 Rev. R0
5. Add IPHC configuration again and do a shut/no shut.
Workaround: There is no workaround.
• CSCtf86865
Symptoms: Enhanced FlexWAN with scaled DLFI setup crashes on doing shut/no shut on ATM
interface.
Conditions: The symptom is observed with the following steps:
1. 256 dLFIoATM interfaces on a single PA.
2. 50 Mbps traffic includes 10 Mbps of 64 byte + 20 Mbps of TCP + 20 Mbps of UDP.
3. Perform a shut/no shut on ATM interface.
Workaround: There is no workaround.
• CSCtf90692
Symptoms: There is an ipservices build failure due to the fix for CSCtf51332.
Conditions: The build fails with the below compilation error:
const/common-rp/fm-earl7/fm_pbr_earl7.c@@ ((,),) obj-4k-draco2-mp-earl7 obj-7k-
sup3-rp-earl7 obj-m8500-sup3-rp-earl7
const/common-rp/fm-earl7/fm_pbr_earl7.c:593: relocation truncated to fit:
R_PPC_REL24 cmfi_feature_alloc_vlan_rcv_vrf
const/common-rp/fm-earl7/fm_pbr_earl7.c:593: undefined reference to
`cmfi_feature_alloc_vlan_rcv_vrf'
Workaround: There is no workaround.
• CSCtf90970
Symptoms: TX CPU might crash on a Cisco 7600 SIP-200 due to a particle chain corruption.
Conditions: The symptom is observed when “ppp multilink interleave” is configured on a multilink
PPP bundle.
Workaround: Disable the “ppp multilink interleave” feature on the multilink PPP bundle.
• CSCtf92354
Symptoms: Traceback is seen when doing a shut and no shut under heavy traffic (100Mbps).
Conditions: The following steps cause this issue:
1. 256 dLFIoATM interfaces on a single PA.
2. Traffic is flowing through all the bundles which is above NDR (100 Mbps) but less than
interface bandwidth (155Mbps). This 100 Mbps traffic includes 20 Mbps of 64 byte + 40 Mbps
of TCP + 40 Mbps of UDP.
3. Do a shut/no shut.
4. Tracebacks will be seen.
Workaround: There is no workaround.
• CSCtf96118
Symptoms: A standby RSP that is supposed to start with SSO mode starts with RPR mode due to
the following error.
Config Sync: Bulk-sync failure due to Servicing Incompatibility. Please check
full list of mismatched commands via:
show redundancy config-sync failures mcl
Config Sync: Starting lines from MCL file:
-no mls flow ipv6
Comentarios a estos manuales