Caveats for Cisco IOS Release 12.2(33)SRD through 12.2(33)SRD8
OL-10394-05 Rev. R0
Conditions: The symptom is observed when an existing service policy is on a interface. The interface
is added to an MLP bundle without manually removing the service policy.
Workaround 1: Before adding the interface to the MLP bundle, remove the existing service policy
configuration with the no service-policy command.
Workaround 2: If the link is already flapping, remove the MLP configuration with the no ppp
multilink command then reapply the same service policy and remove it:
service-policy XXXXXXXXX
no service policy XXXXXXXX
Check that the queuing has been removed with show hqf interface XXXX. The command should
return no output if the queuing has been removed. Add back the MLP configuration:
ppp multilink
ppp multilink group YYY etc
Workaround 3: Remove the channel-group and re-add it, if the interface was created as part of a
channel-group.
Workaround 4: Use the wr mem command and reload the router.
CSCsy24691
Symptoms: For 6KW DC PS, some or all of the four power-input sensors are missing from SNMP
entries in entPhyiscalTable “power-supply [1-2] power-input [1-4] Sensor”.
Conditions: The symptom is observed with a 6KW DC Power Supply 2.
Workaround: There is no workaround.
CSCsy31601
Symptoms: After switchover on UUT, BGP sessions will not be re-established and the RTRA will
not accept a connection from the UUT.
Conditions: The symptom is observed only if “timer 0 0” (hold-down timer never expires) is
configured on DUT (where switchover is done) and there are no route changes on the RTRA. If any
route is advertised or withdrawn by RTRA, the peer will send a TCP reset.
Workaround: Do not use “timer 0 0” (hold-down timer never expires).
Further Problem Description: This is observed in internal testing and is a rare case scenario.
CSCsy34533
Symptoms: Fast switching does not work when “dot1q native vlan” is configured on the interface.
Conditions: The issue is seen with a Cisco 7600 series router.
Workaround: Remove CLNS fast switching from the interface where the VLAN is configured.
CSCsy34805
Symptoms: Police rate configuration is lost after reload.
Conditions: The following configuration:
police rate 40000000 burst 1250000 peak-rate 60000000 peak-burst 1875000
is saved in the router configuration as:
police rate 40000000 bps burst 1250000 peak-rate 60000000 peak-burst 1875000
This configuration is invalid and is rejected.
Workaround: Configure using bytes per second and bytes as qualifiers:
police rate 40000000 bps burst 1250000 bytes peak-rate 60000000 bps peak-burst 1875000
bytes